Equipment & Repair Management
EQUIPMENT

Mower #16 - Wright Stander X

Wright Stander X

Operable
Type
Stander 52
Hours
1038.7
Miles
—
VIN / Serial
141136AX
Plate
—
Tag Exp.
—
Insurance Exp.
—
Inspection Status
—
Inspection Expiration
—
Purchase Date
—
Warranty Expiration
—
Separate Engine Warranty
No
Notes
—
Equipment QR code Scan this label to return here.
6 Open Repairs Open the Repairs / Maintenance tab 10 Repair History 4 completed records

Report a Problem

Enter current hours or current mileage. At least one is required.
SPREADSHEET VIEW

Repair History

Ticket Type Status Start Work Pickup Problem / Service Diagnosis Parts Parts Price Labor Assigned Submitted By Location Notes
#169 Repair Waiting for Parts 10/12/2026 — Sluggish performance and back fire Emissions canister on side of motor had a vacuum cap with a hole in it causing a vacuum leak and poor performance After doing that fix and operating- discovered further issue.. hydro pump belt tensioner, need spring tool for idler arm replacement. Replaced vacuum cap, hydro pump belt tensioner, need spring tool for idler arm replacement. — — Unassigned Merritt — After replacing cap I operated the machine as intended without any symptoms returning at various throttle ranges. Howard has repeated the process, during additional testing, mower lost about half power while going uphill. Further traige required. After further digging, the belt tensioner for the hydraulic pumps is not holding pressure allowing the belt to slip causing power loss while attempting to supply proper power to go uphill
#182 Repair Waiting for Parts — — Sluggish performance and back fire Emissions canister on side of motor had a vacuum cap with a hole in it causing a vacuum leak and poor performance After doing that fix and operating- discovered further issue.. hydro pump belt tensioner, need spring tool for idler arm replacement. Replaced vacuum cap, hydro pump belt tensioner, need spring tool for idler arm replacement. — — Unassigned Merritt — After replacing cap I operated the machine as intended without any symptoms returning at various throttle ranges. Howard has repeated the process, during additional testing, mower lost about half power while going uphill. Further traige required. After further digging, the belt tensioner for the hydraulic pumps is not holding pressure allowing the belt to slip causing power loss while attempting to supply proper power to go uphill
#159 Repair Waiting for Parts 9/30/2026 — Sluggish performance and back fire Emissions canister on side of motor had a vacuum cap with a hole in it causing a vacuum leak and poor performance After doing that fix and operating- discovered further issue.. hydro pump belt tensioner, need spring tool for idler arm replacement. Replaced vacuum cap, hydro pump belt tensioner, need spring tool for idler arm replacement. Crank bolt has gonbe missing ordered new from equipko — — Brad Merritt Shop After replacing cap I operated the machine as intended without any symptoms returning at various throttle ranges. Howard has repeated the process, during additional testing, mower lost about half power while going uphill. Further traige required. After further digging, the belt tensioner for the hydraulic pumps is not holding pressure allowing the belt to slip causing power loss while attempting to supply proper power to go uphill
#106 Repair Waiting for Parts 9/28/2026 — Sluggish performance and back fire Emissions canister on side of motor had a vacuum cap with a hole in it causing a vacuum leak and poor performance After doing that fix and operating- discovered further issue.. hydro pump belt tensioner, need spring tool for idler arm replacement. Replaced vacuum cap, hydro pump belt tensioner, need spring tool for idler arm replacement. — — Unassigned Merritt — After replacing cap I operated the machine as intended without any symptoms returning at various throttle ranges. Howard has repeated the process, during additional testing, mower lost about half power while going uphill. Further traige required. After further digging, the belt tensioner for the hydraulic pumps is not holding pressure allowing the belt to slip causing power loss while attempting to supply proper power to go uphill
#105 Repair Waiting for Parts 9/9/2026 — Sluggish performance and back fire Emissions canister on side of motor had a vacuum cap with a hole in it causing a vacuum leak and poor performance Replaced vacuum cap, hydro pump belt tensioner — — Unassigned Merritt — After replacing cap I operated the machine as intended without any symptoms returning at various throttle ranges. Howard has repeated the process, during additional testing, mower lost about half power while going uphill. Further traige required. After further digging, the belt tensioner for the hydraulic pumps is not holding pressure allowing the belt to slip causing power loss while attempting to supply proper power to go uphill
#72 Repair Completed 8/31/2026 — Unit loses power and starts to back fire. When symptoms show strong smell of propane is apparent. fluid from hydraulic line blowing has gotten inbto intake system. will need tear down, cleaning, then reassembly. At this time no parts are needed, — — — Unassigned Brad — —
#69 Repair Completed 8/27/2026 — Fluid leak Left side hydraulic hose has a hole in it, immediately starts streaming out when mower is started. left side 35 inch high pressure hydraulic hose PN 33410126, hydraulic system filled and air pockets removed, hydraulic system repaired and sealed, air has been removed, back firing and throttle sticking is now the issue — — Brad Brad Shop —
#56 Repair In Progress 8/26/2026 — Fluid leak Left side hydraulic hose has a hole in it, immediately starts streaming out when mower is started. left side 35 inch high pressure hydraulic hose PN 33410126, hydraulic system filled and air pockets removed, hydraulic system repaired and sealed, air has been removed, back firing and throttle sticking is now the issue — — Brad Brad Shop —
#32 Repair Completed 8/14/2026 — PTO failure, operation intermittent Wiring faulty and failed fuel safety switch New harnesses from wright and blossman, replaced PTO switch and clutch, new operator safety switch — 3 Brad Brad Shop Replaced electrical harness, cleaned up burnt sections of wiring and replaced broken portion of harness, service inspection, replaced air filter. Unit is ready for field use.
#11 Repair Completed 8/13/2026 — PTO failure, operation intermittent Wiring faulty and failed fuel safety switch. Primary harness has broken switch wiring, lower harness has broken ground for PTO system. New harnesses from wright and blossman, replaced PTO switch and clutch, new operator safety switch — 3 Brad Brad Shop —

Complete Equipment Timeline

Repairs, service, equipment changes, and renewal dates in one history.

58 items
Repair / Maintenance

Sluggish performance and back fire

Unassigned · Emissions canister on side of motor had a vacuum cap with a hole in it causing a vacuum leak and poor performance After doing that fix and operating- discovered further issue.. hydro pump belt tensioner, need spring tool for idler arm replacement. · After replacing cap I operated the machine as intended without any symptoms returning at various throttle ranges. Howard has repeated the process, during additional testing, mower lost about half power while going uphill. Further traige required. After further digging, the belt tensioner for the hydraulic pumps is not holding pressure allowing the belt to slip causing power loss while attempting to supply proper power to go uphill

Waiting for Parts
Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair / Maintenance

Sluggish performance and back fire

Unassigned · Emissions canister on side of motor had a vacuum cap with a hole in it causing a vacuum leak and poor performance After doing that fix and operating- discovered further issue.. hydro pump belt tensioner, need spring tool for idler arm replacement. · After replacing cap I operated the machine as intended without any symptoms returning at various throttle ranges. Howard has repeated the process, during additional testing, mower lost about half power while going uphill. Further traige required. After further digging, the belt tensioner for the hydraulic pumps is not holding pressure allowing the belt to slip causing power loss while attempting to supply proper power to go uphill

Waiting for Parts
Repair

Day-of email sent

Day-of email sent for Mower #16 - Wright Stander X.

Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair / Maintenance

Sluggish performance and back fire

Shop · Brad · Emissions canister on side of motor had a vacuum cap with a hole in it causing a vacuum leak and poor performance After doing that fix and operating- discovered further issue.. hydro pump belt tensioner, need spring tool for idler arm replacement. · After replacing cap I operated the machine as intended without any symptoms returning at various throttle ranges. Howard has repeated the process, during additional testing, mower lost about half power while going uphill. Further traige required. After further digging, the belt tensioner for the hydraulic pumps is not holding pressure allowing the belt to slip causing power loss while attempting to supply proper power to go uphill

Waiting for Parts
Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair / Maintenance

Sluggish performance and back fire

Unassigned · Emissions canister on side of motor had a vacuum cap with a hole in it causing a vacuum leak and poor performance After doing that fix and operating- discovered further issue.. hydro pump belt tensioner, need spring tool for idler arm replacement. · After replacing cap I operated the machine as intended without any symptoms returning at various throttle ranges. Howard has repeated the process, during additional testing, mower lost about half power while going uphill. Further traige required. After further digging, the belt tensioner for the hydraulic pumps is not holding pressure allowing the belt to slip causing power loss while attempting to supply proper power to go uphill

Waiting for Parts
Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair / Maintenance

Sluggish performance and back fire

Unassigned · Emissions canister on side of motor had a vacuum cap with a hole in it causing a vacuum leak and poor performance · After replacing cap I operated the machine as intended without any symptoms returning at various throttle ranges. Howard has repeated the process, during additional testing, mower lost about half power while going uphill. Further traige required. After further digging, the belt tensioner for the hydraulic pumps is not holding pressure allowing the belt to slip causing power loss while attempting to supply proper power to go uphill

Waiting for Parts
Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair

Updated

Updated repair: Sluggish performance and back fire.

Repair

Ticket submitted

Ticket submitted by Merritt: Sluggish performance and back fire

Repair

Completed

Updated repair: Unit loses power and starts to back fire. When symptoms show strong smell of propane is apparent..

Repair / Maintenance

Unit loses power and starts to back fire. When symptoms show strong smell of propane is apparent.

Unassigned · fluid from hydraulic line blowing has gotten inbto intake system. will need tear down, cleaning, then reassembly. At this time no parts are needed,

Completed
Repair

Updated

Updated repair: Unit loses power and starts to back fire. When symptoms show strong smell of propane is apparent..

Repair

Updated

Updated repair: Unit loses power and starts to back fire. When symptoms show strong smell of propane is apparent..

Repair

Ticket submitted

Ticket submitted by Brad: Unit loses power and starts to back fire. When symptoms show strong smell of propane is apparent.

Repair

Completed

Updated repair: Fluid leak.

Repair / Maintenance

Fluid leak

Shop · Brad · Left side hydraulic hose has a hole in it, immediately starts streaming out when mower is started.

Completed
Equipment

Equipment information updated

Hours, mileage, identification, status, or notes were updated.

Operable
Repair

Day-of email sent

Day-of email sent for Mower #16 - Wright Stander X.

Repair

Overdue email sent

Overdue email sent for Mower #16 - Wright Stander X.

Repair

Past due copy created

Created an unscheduled Not Started copy of past-due repair: Fluid leak.

Repair

Day-of email sent

Day-of email sent for Mower #16 - Wright Stander X.

Repair / Maintenance

Fluid leak

Shop · Brad · Left side hydraulic hose has a hole in it, immediately starts streaming out when mower is started.

In Progress
Repair

Day-of email sent

Day-of email sent for Mower #16 - Wright Stander X.

Repair

Updated

Updated repair: Fluid leak.

Repair

Updated

Updated repair: Fluid leak.

Repair

Day-of email sent

Day-of email sent for Mower #16 - Wright Stander X.

Repair

Updated

Updated repair: Fluid leak.

Repair

Updated

Updated repair: Fluid leak.

Repair

Updated

Updated repair: Fluid leak.

Repair

Ticket submitted

Ticket submitted by Brad: Fluid leak

Repair

Completed

Updated repair: PTO failure, operation intermittent.

Repair / Maintenance

PTO failure, operation intermittent

Shop · Brad · Wiring faulty and failed fuel safety switch. Primary harness has broken switch wiring, lower harness has broken ground for PTO system.

Completed
Repair

Completed

Updated repair: PTO failure, operation intermittent.

Repair / Maintenance

PTO failure, operation intermittent

Shop · Brad · Wiring faulty and failed fuel safety switch · Replaced electrical harness, cleaned up burnt sections of wiring and replaced broken portion of harness, service inspection, replaced air filter. Unit is ready for field use.

Completed
Repair

Day-of email sent

Day-of email sent for Mower #16 - Wright Stander X.

Repair

Updated

Updated repair: PTO failure, operation intermittent.

Repair

Day-of email sent

Day-of email sent for Equipment.

Repair

Day-of email sent

Day-of email sent for Mower #16 - Wright Stander X.

Repair

Updated

Updated repair: PTO failure, operation intermittent.

Equipment

Equipment record created

Mower #16 - Wright Stander X

Repair

Day-of email sent

Day-of email sent for Equipment.

Repair

Updated

Updated repair: PTO failure, operation intermittent.

Repair

Day-of email sent

Day-of email sent for Equipment.

Repair

Updated

Updated repair: PTO failure, operation intermittent.

Repair

Updated

Updated repair: PTO failure, operation intermittent.

Repair

Ticket submitted

Ticket submitted by Brad: PTO failure, operation intermittent

An unhandled error has occurred. Reload 🗙

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.