Mower #5 - Wright Stander X
Wright Stander X
- Type
- Stander 52
- Hours
- 966.1
- Miles
- —
- VIN / Serial
- 139299NF
- Plate
- —
- Tag Exp.
- —
- Insurance Exp.
- —
- Inspection Status
- —
- Inspection Expiration
- —
- Purchase Date
- —
- Warranty Expiration
- —
- Separate Engine Warranty
- No
- Notes
- —
Report a Problem
Repair History
| Ticket | Type | Status | Start Work | Pickup | Problem / Service | Diagnosis | Parts | Parts Price | Labor | Assigned | Submitted By | Location | Notes |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| #189 | Repair | Completed | 10/7/2026 | — | poor performance | After verifying the main issues typically associated with poor performance, it was found that the regulator for the propane system was getting clogged by heavy mineral build up in the regulator body and the inlet filter. | Brake parts cleaner | — | — | Unassigned | Brad | — | Disassembled the regulator, cleaned metal and similar areas, gently wiped down rubber diaphragm on both sides of assembly, unit now runs at full throttle without performance dro pwith and without PTO usage. Clear for field use. |
| #156 | Repair | Completed | 10/1/2026 | — | performance is restricted | air valve in intake melted and broken, throttle body clogging up, spark plugs fouled, ignition coils, losing magnetic pick up, air filter clogged, cooling fins on engine clogged, oil dip stick o-ring failed, oil entering intake mixing with propane vapor, overall condition of unit was poor, cracked and dry rotted hose from engine to intake. | New plugs, igntion coils, hose, air valve, air filter | — | — | Unassigned | Brad | — | tore down intake system, cleaned throttle assembly, intake inlet, intake manifold, inspected all gaskets, replaced spark plugs and ignition coils, attempted to clean air filter, element was hard packed, replaced air filter element, cleaned unit overall, swapped dipstick tube with good one, Unable to confirm location of oil leak at this time. Unit leaks oil when stationary and off. adjusted throttle assembly, cleaned hardware, ensured proper timing placement of ignition coils,. Replaced intake hose with new hose from Advance Auto. |
| #104 | Repair | Completed | 9/9/2026 | — | Power failure when pto is enaged | PTO clutch locking up causing power failure. | PTO Clutch | — | — | Brad | Brad | Shop | Replaced PTO Clutch confirmed no power drain under pto operation. Cleared for field |
| #95 | Repair | Completed | 9/8/2026 | — | Fails to stay running | During inspection foudn that the primary ground to the engine and to the fuel safety lock out were loose and had a bad connection. | Replaced fuel saftey harness and relay, cleaned adn tightened primary ground to engine. Test drove and ran PTO system, no symptoms of failure or lower performance. Cleared for field use | — | — | Unassigned | Brad | — | — |
| #86 | Repair | Completed | 9/2/2026 | — | shut off during operation on site | Upon cleaning the unit, brought in with assumption there was a broken wire somewhere, no wiring was damged. Unit works as it should. | — | — | — | Unassigned | Brad | — | Added a couple of zip ties to prevent wire harness catching the deck handle. No damages in harness found. Unit starts and operates as intended. Cleared for field use. |
Complete Equipment Timeline
Repairs, service, equipment changes, and renewal dates in one history.
Completed
Updated repair: poor performance.
poor performance
Unassigned · After verifying the main issues typically associated with poor performance, it was found that the regulator for the propane system was getting clogged by heavy mineral build up in the regulator body and the inlet filter. · Disassembled the regulator, cleaned metal and similar areas, gently wiped down rubber diaphragm on both sides of assembly, unit now runs at full throttle without performance dro pwith and without PTO usage. Clear for field use.
CompletedTicket submitted
Ticket submitted by Brad: poor performance
Completed
Updated repair: performance is restricted.
performance is restricted
Unassigned · air valve in intake melted and broken, throttle body clogging up, spark plugs fouled, ignition coils, losing magnetic pick up, air filter clogged, cooling fins on engine clogged, oil dip stick o-ring failed, oil entering intake mixing with propane vapor, overall condition of unit was poor, cracked and dry rotted hose from engine to intake. · tore down intake system, cleaned throttle assembly, intake inlet, intake manifold, inspected all gaskets, replaced spark plugs and ignition coils, attempted to clean air filter, element was hard packed, replaced air filter element, cleaned unit overall, swapped dipstick tube with good one, Unable to confirm location of oil leak at this time. Unit leaks oil when stationary and off. adjusted throttle assembly, cleaned hardware, ensured proper timing placement of ignition coils,. Replaced intake hose with new hose from Advance Auto.
CompletedUpdated
Updated repair: performance is restricted.
Updated
Updated repair: performance is restricted.
Ticket submitted
Ticket submitted by Brad: performance is restricted
Completed
Updated repair: Power failure when pto is enaged.
Power failure when pto is enaged
Shop · Brad · PTO clutch locking up causing power failure. · Replaced PTO Clutch confirmed no power drain under pto operation. Cleared for field
CompletedDay-of email sent
Day-of email sent for Mower #5 - Wright Stander X.
Updated
Updated repair: Power failure when pto is enaged.
Ticket submitted
Ticket submitted by Brad: Power failure when pto is enaged
Completed
Updated repair: Fails to stay running.
Equipment information updated
Hours, mileage, identification, status, or notes were updated.
OperableCompleted
Updated repair: Fails to stay running.
Completed
Updated repair: Fails to stay running.
Fails to stay running
Unassigned · During inspection foudn that the primary ground to the engine and to the fuel safety lock out were loose and had a bad connection.
CompletedUpdated
Updated repair: Fails to stay running.
Ticket submitted
Ticket submitted by Brad: Fails to stay running
Completed
Updated repair: shut off during operation on site.
shut off during operation on site
Unassigned · Upon cleaning the unit, brought in with assumption there was a broken wire somewhere, no wiring was damged. Unit works as it should. · Added a couple of zip ties to prevent wire harness catching the deck handle. No damages in harness found. Unit starts and operates as intended. Cleared for field use.
CompletedEquipment record created
Mower #5 - Wright Stander X
Ticket submitted
Ticket submitted by Brad: shut off during operation on site